Home Insulation R-Value Guide
Find the recommended R-values for your climate zone — attic, walls, floors, and basement — based on U.S. Department of Energy (DOE) and ENERGY STAR guidelines.
R-Value Target & Depth Estimator
Zone 4C (coastal Pacific NW) uses floor R30 and wall R15 sheathing / R19 batt, grouping with Zones 5–6.
Recommended Specification
Target Thermal Resistance
R-60
ENERGY STAR / DOE guideline for Zone 4
Estimated Material Depth
~17.1 inches
Based on Blown-in cellulose (15.8–18.8 in. range).
Depth & Settling Note
Loose-fill materials settle after installation (up to 15–20% for blown cellulose). Install to the manufacturer's labeled initial thickness to achieve settled R-value.R-Value by Climate Zone and Area
Department of Energy recommended levels for existing residential structures:
| Climate Zone | Attic (Uninsulated) | Attic (Existing R11+) | Floor | Wall Sheathing / Cavity |
|---|---|---|---|---|
| Zone 1 | R-30 | R-25 | R-13 | R13 |
| Zone 2 | R-49 | R-38 | R-13 | R13 |
| Zone 3 | R-49 | R-38 | R-19 | R5 + R13 |
| Zone 4 | R-60 | R-49 | R-19 | R10 + R13 |
| Zone 5 | R-60 | R-49 | R-30 | R15 + R19 |
| Zone 6 | R-60 | R-49 | R-30 | R15 + R19 |
| Zone 7 | R-60 | R-49 | R-38 | R15 + R19 |
| Zone 8 | R-60 | R-49 | R-38 | R15 + R19 |
Common Insulation Materials Comparison
Fiberglass batts
R-2.9 – 3.8 / inPre-cut blankets of spun glass fibers. The most common DIY batt insulation. Available faced (with a vapor retarder) or unfaced.
- Affordable and widely available
- DIY-friendly for standard framing
- Non-combustible
- Gaps and compression greatly reduce performance
- Poor air barrier
- Itches during handling
Blown-in fiberglass
R-2.2 – 2.7 / inLoose fiberglass blown into attics with a machine. Good for covering irregular or obstructed attic spaces.
- Fills around joists and obstructions
- No cutting required
- Lightweight
- Lower R-per-inch than cellulose
- Can settle over time
- Requires blowing equipment
Blown-in cellulose
R-3.2 – 3.8 / inShredded, treated recycled paper blown dry or damp-sprayed. ENERGY STAR cites common materials at R-3 to R-3.5 per inch.
- Higher R-per-inch than blown fiberglass
- Made from recycled content
- Better air sealing than batts
- Can settle — over-fill to compensate
- Absorbs moisture
- Dust during installation
Open-cell spray foam
R-3.5 – 3.9 / inSpray-applied polyurethane that expands to fill cavities. Open-cell is softer and more permeable than closed-cell.
- Expands to seal gaps and cracks
- Good air barrier
- Sound-dampening
- Lower R-per-inch than closed-cell
- Vapor-permeable
- Professional installation typically required
Closed-cell spray foam
R-6 – 7 / inDense spray foam that acts as insulation, air barrier, and vapor retarder in one. Highest R-per-inch of common materials.
- Highest R-per-inch available
- Air barrier and vapor retarder
- Adds structural rigidity
- Expensive
- Requires professional installation
- Blowing agents have environmental considerations
Mineral wool (rock/slag)
R-3 – 3.3 / inBatts or loose-fill made from molten rock or slag. Naturally fire-resistant and denser than fiberglass.
- Fire-resistant without added chemicals
- Better sound-dampening than fiberglass
- Does not settle as much
- More expensive than fiberglass
- Heavier and harder to cut
- Dust during handling
Essential Air-Sealing Steps Before Insulating
Air-Seal First, Then Insulate
Insulation resists conductive heat transfer, but it does NOT stop air leaks. Before adding attic insulation:
- Seal electrical wire penetrations and ceiling electrical boxes with expanding foam.
- Foam around plumbing vent stacks and flues (use fire-rated sealant near chimneys).
- Weatherstrip and insulate the attic access hatch or drop-down ladder.
- Install rafter vent baffles to maintain a continuous air path from soffit vents to ridge exhaust.
Frequently Asked Questions
It depends on your climate zone and existing insulation. In Zones 4–8, ENERGY STAR recommends R-60 for an uninsulated attic and R-49 when 3–4 inches of insulation already exists. In Zones 2–3 the target is R-49 (R-38 with existing insulation), and in Zone 1 it is R-30 (R-25 with existing insulation). Use the tool above to get a specific recommendation for your zone.
Authoritative References & Standards
R-value table by climate zone (based on 2021 IECC).
R-value recommendations and material R-per-inch data.
R-3 to R-3.5 per inch for common materials; air sealing guidance.
Ventilation and insulation interaction.